几种常见的小电流接地选线方法对比

发(fa)布日期:2023-06-26 信息来源:丹华昊博

小电流接地选线装置历经三(san)十几年的研究和(he)发(fa)展,已经十分成熟,市场应用数(shu)量已经不计(ji)其数(shu)。小(xiao)电(dian)流(liu)接地选(xuan)线装置厂家的技(ji)(ji)术也参差不齐(qi),总体(ti)(ti)来(lai)说,运用广泛的还(hai)是华(hua)北(bei)电(dian)力(li)大(da)学杨(yang)以涵教(jiao)授提出的六种方法两种技(ji)(ji)术,即(ji)智(zhi)能(neng)群(qun)体(ti)(ti)比(bi)幅比(bi)相法、谐(xie)波比(bi)幅比(bi)相法、小(xiao)波法、首半波法、有(you)(you)功(gong)分量法、能(neng)量法、零序电(dian)流(liu)突变量法,有(you)(you)效(xiao)域技(ji)(ji)术和(he)连续选(xuan)线技(ji)(ji)术。

现(xian)就市场(chang)上使(shi)用(yong)较多的几种选线方法(fa)作如下(xia)对比:

1、 反应零(ling)序(xu)电流大小(xiao)的(de)接(jie)地保护

长线路(lu)(lu)(lu)对(dui)地电(dian)(dian)(dian)(dian)容大,电(dian)(dian)(dian)(dian)容电(dian)(dian)(dian)(dian)流(liu)(liu)大; 短线路(lu)(lu)(lu)对(dui)地电(dian)(dian)(dian)(dian)容小(xiao),电(dian)(dian)(dian)(dian)容电(dian)(dian)(dian)(dian)流(liu)(liu)小(xiao),有(you)时(shi)保护易(yi)误判,例如短线路(lu)(lu)(lu)发生(sheng)接(jie)地故(gu)障,其零(ling)(ling)序电(dian)(dian)(dian)(dian)流(liu)(liu)是非故(gu)障长线路(lu)(lu)(lu)电(dian)(dian)(dian)(dian)容电(dian)(dian)(dian)(dian)流(liu)(liu)之和,二者的零(ling)(ling)序电(dian)(dian)(dian)(dian)流(liu)(liu)数(shu)值(zhi)相差(cha)不大,保护装置(zhi)很难区分。另(ling)外系统进行倒闸操作,运行状况变(bian)化,电(dian)(dian)(dian)(dian)容电(dian)(dian)(dian)(dian)流(liu)(liu)分布也变(bian)化,故(gu)动作值(zhi)难以整定。

2、 反应零序电(dian)流方的(de)接地(di)保(bao)护

利用故障(zhang)线(xian)(xian)(xian)路(lu)零(ling)(ling)(ling)(ling)序(xu)电(dian)流滞(zhi)后零(ling)(ling)(ling)(ling)序(xu)电(dian)压90°,非(fei)故障(zhang)线(xian)(xian)(xian)路(lu)零(ling)(ling)(ling)(ling)序(xu)电(dian)流超前(qian)零(ling)(ling)(ling)(ling)序(xu)电(dian)压90°作为判据,但是当(dang)测得的零(ling)(ling)(ling)(ling)序(xu)电(dian)流较小(如(ru)故障(zhang)线(xian)(xian)(xian)路(lu)是长线(xian)(xian)(xian)路(lu),而非(fei)故障(zhang)线(xian)(xian)(xian)路(lu)是短线(xian)(xian)(xian)路(lu)),零(ling)(ling)(ling)(ling)序(xu)电(dian)流复相量模值较小,相角(jiao)差就较大(da),就象时钟(zhong)太短,难以看清位置(相角(jiao))一样,易造成误(wu)动。此类保护(hu)只适用于稳(wen)定(ding)金属(shu)接地(di),而接地(di)故障(zhang)大(da)多是间歇性或瞬(shun)时性弧光接地(di),难以准确判断。

3、 群体比幅(fu)比相法

对所有的(de)线(xian)(xian)路(lu)(lu)的(de)零序电流(liu)大(da)小和(he)方(fang)向进行(xing)综合比较,判(pan)别出(chu)故障线(xian)(xian)路(lu)(lu)。CPU采(cai)(cai)样一个(ge)(ge)点约需100μs,以一条线(xian)(xian)路(lu)(lu)在(zai)一个(ge)(ge)工频同(tong)(tong)期(20ms)内最少得(de)采(cai)(cai)集(ji)16个(ge)(ge)点计(ji)算(suan),单(dan)CPU采(cai)(cai)集(ji)多(duo)条线(xian)(xian)路(lu)(lu)时,一个(ge)(ge)周(zhou)波(bo)内最多(duo)只(zhi)能采(cai)(cai)集(ji)12条线(xian)(xian)路(lu)(lu)的(de)数据(ju)(ju),完成数据(ju)(ju)采(cai)(cai)集(ji)后,CPU进入数据(ju)(ju)处理、计(ji)算(suan)、判(pan)别,在(zai)此(ci)期间CPU无法继续采(cai)(cai)样工作,导致大(da)量数据(ju)(ju)丢失。对于不稳定(ding)弧(hu)光接地,不同(tong)(tong)周(zhou)波(bo)内数据(ju)(ju)变化较大(da),用它们进行(xing)比较必然造成判(pan)线(xian)(xian)错误,故每条线(xian)(xian)路(lu)(lu)至少采(cai)(cai)集(ji)2~3个(ge)(ge)周(zhou)波(bo)的(de)数据(ju)(ju),才能正确判(pan)别出(chu)故障线(xian)(xian)路(lu)(lu)。

如每(mei)条(tiao)出线都有自己的(de)(de)CPU,这(zhei)些(xie)CPU同时启动、采集数据(ju)、计算(suan)比(bi)较,实现了并行不间断(duan)处理数据(ju),解决(jue)了数据(ju)丢(diu)失问(wen)题,准确判(pan)定故障(zhang)线路(lu)(lu),从所有的(de)(de)线路(lu)(lu)中(zhong)选出零序(xu)电流最大的(de)(de)三(san)条(tiao)线(1)>(2)>(3),若(1)与(yu)(2)、(3)反相,则(1)是接地线; 若(1)、(2)、(3)同相,则判(pan)母线故障(zhang)。

因此,由于中性点不(bu)接(jie)地电(dian)网单相接(jie)地的(de)瞬(shun)时(shi)性和间(jian)歇性,小电(dian)流接(jie)地选线装置难以准确(que)判(pan)断,为确(que)保(bao)不(bu)接(jie)地系(xi)统的(de)稳定运行,一定要选用理论上切(qie)实可(ke)行并有多(duo)年运行经验(yan)的(de)设(she)备。